I. Preparation before Installation

1、Check the completeness of accessories

Check if all panel components (such as the panel body, screws, snap-fit connections, sealing strips, etc.) are complete to avoid installation interruptions or rework due to missing parts.

Confirm that the panel model matches the air purifier main unit to avoid installation failure or abnormal operation due to incompatible size or interface.

Clean install environment

2、Clean install environment

Clean the dust, oil stains, or residual glue on the surface of the host to ensure that the panel and the contact surface of the host are flat and clean, preventing poor sealing or abnormal noise caused by impurities.


If you need to remove the old panel, use a specialized tool (such as a plastic pry bar) to avoid scratching the host casing.


3、Power-off operation

Be sure to cut off the power supply of the air purifier before installation to prevent the risk of electric shock, especially when it involves circuit connections or internal component adjustments.

II. Key Points of the Installation Process

1、Alignment, Positioning, and Fixing:

Snap-in Panel: Align the edge of the panel with the host's card slot, gently press until you hear a "click" sound to confirm that the snap is fully engaged. Avoid applying excessive force to prevent the snap from breaking.


Screw-fixing panel: Use the accompanying screwdriver to tighten the screws diagonally in sequence, ensuring even force distribution to prevent panel deformation or excessive gaps.


Magnetic Panel: Directly attach to the corresponding position on the host, check if the magnetic force is stable to avoid falling off due to vibration.


2、 Sealed treatment

If there is a sealing strip (such as a silicone strip) between the panel and the main unit, ensure that it fully covers the contact surface without any folds or gaps to prevent air leakage from affecting the purification efficiency.


For high-end models (such as those with UV sterilization function), it is necessary to check whether the sealing ring is seamlessly connected with the filter screen to avoid the risk of UV leakage.


3、Line connection (if applicable)

If the panel integrates a display, sensor, or touch module, you need to connect the internal wiring according to the instructions, paying attention to the plug orientation and interface labels to avoid short circuits or signal interference.


After connecting, gently pull the wires to confirm they are securely fixed to prevent loosening and poor contact.


III. Post-Installation Inspection and Testing

1、Appearance and Function Verification

Check if the gap between the panel and the host is even, without any warping, tilting, or excessive gaps.


Turn on the air purifier, test whether the panel buttons/touch response is sensitive, and whether the display data (such as air quality, wind speed, etc.) are displayed normally.


Simulate the child lock function (e.g., long press for 2 seconds), confirm whether the operation interface is locked to prevent children from accidentally touching it.


2、Run stability tests

Run the air purifier for 10-15 minutes, observe whether there are any abnormal sounds, heating or vibrations in the panel area.

Check if the air intake grill is unobstructed, avoid improper installation of the panel that may hinder airflow and affect the purification effect.


3、Safety Protection Confirmation

For models with ultraviolet sterilization function, use an ultraviolet intensity detection card to verify the sealing of the panel, ensuring no leakage.

Check if the filter installation indicator light is functioning properly (such as the filter life reminder feature) to avoid misjudging the filter status due to incorrect panel installation.


IV. Special Situation Precautions

1、 Installation in damp environments

Avoid installing air purifiers in high-humidity areas such as bathrooms and kitchens to prevent the internal circuitry of the control panel from short-circuiting due to dampness. If necessary, choose products with a suitable waterproof rating (e.g., IPX4).


2、High-temperature environment installation

Keep away from heat sources such as radiators, ovens to prevent the panel material (such as acrylic) from deforming or aging due to high temperatures.


3、Child and Pet Protection

Ensure that the panel is securely installed to prevent it from falling off due to children climbing or pets scratching. If the edges of the panel are sharp, you can install edge guards.

V. Maintenance and Replacement Suggestions

1、 Regular cleaning

Wipe the surface of the panel with a slightly damp soft cloth, avoid using corrosive cleaners such as alcohol or gasoline, to prevent damage to the touch-sensitive coating or display screen.


2、Replace aging panels in a timely manner

If the panel shows cracks, discoloration, or touch malfunctioning, contact after-sales service to replace original parts to avoid equipment failure caused by using incompatible products.


3、Professional Repair

When it comes to replacing internal wiring or sensors, it is recommended that professionals handle the operation to prevent damage to core components due to improper disassembly.










Social

Looking For A Reliable User Interface Products Manufacturer?

User Interface Boards (UIB)

Displays

Input Interfaces

Services

Resources

CONTACT INFO
Tel: +86-134-3741-0111
Add: 1/F, Building 3 of Hesen Industrial Park 523926, Huailin Rd., Huaide Area, Humen Town, Dongguan, Guangdong, China
Copyright © 2024 LUPHI All Rights Reserved.